Nginx+Keepalived主从双机热备+自动切换
1 安装配置nginx
参考: http://www.cnblogs.com/jager/p/4388202.html
2 安装配置keepalived
tar xvf keepalived-1.2.18.tar.gz
cd keepalived-1.2.18 ./configure
make && make install cd /etc/
mkdir keepalived
vim /etc/keepalived/chk_nginx.keepalived.sh
chmod a+x /etc/keepalived/chk_nginx.keepalived.sh cd /usr/local/etc/keepalived/
vim /usr/local/etc/keepalived/keepalived.conf
chk_nginx.keepalived.sh:
keepalived.conf:
keepalived.conf(另外一台备机上的)
3 启动相关服务
启动nginx
/usr/local/nginx/sbin/nginx
启动 keepalived
killall keepalived
keepalived -f /usr/local/etc/keepalived/keepalived.conf
4 keepalive自动切换演练
通过 ip a 可以查看到当前的vip连在哪台服务器上,测试自动切换可以killall keepalived来模拟nginx服务器宕机,然后再用ip a来查看当前的vip,比如nginx 主机宕机之后vip应该自动漂移到nginx备机服务器上,当nginx主机恢复之后keepalived自动将vip重新飘回主机
5 keepalive相关参数说明
! Configuration File for keepalived global_defs {
notification_email {
admin@lvtao.net #设置报警邮件地址,可以设置多个,每行一个。 需开启本机的sendmail服务
}
notification_email_from admin@lvtao.net #设置邮件的发送地址
smtp_server 127.0.0.1 #设置smtp server地址
smtp_connect_timeout 30 #设置连接smtp server的超时时间
router_id LVS_DEVEL #表示运行keepalived服务器的一个标识。发邮件时显示在邮件主题的信息
} vrrp_instance VI_1 {
state MASTER #指定keepalived的角色,MASTER表示此主机是主服务器,BACKUP表示此主机是备用服务器
interface eth0 #指定HA监测网络的接口
virtual_router_id 51 #虚拟路由标识,这个标识是一个数字,同一个vrrp实例使用唯一的标识。即同一vrrp_instance下,MASTER和BACKUP必须是一致的
priority 100 #定义优先级,数字越大,优先级越高,在同一个vrrp_instance下,MASTER的优先级必须大于BACKUP的优先级
advert_int 1 #设定MASTER与BACKUP负载均衡器之间同步检查的时间间隔,单位是秒
authentication { #设置验证类型和密码
auth_type PASS #设置验证类型,主要有PASS和AH两种
auth_pass 1111 #设置验证密码,在同一个vrrp_instance下,MASTER与BACKUP必须使用相同的密码才能正常通信
}
virtual_ipaddress { #设置虚拟IP地址,可以设置多个虚拟IP地址,每行一个
10.0.0.148
}
} virtual_server 10.0.0.148 80 { #设置虚拟服务器,需要指定虚拟IP地址和服务端口,IP与端口之间用空格隔开
delay_loop 6 #设置运行情况检查时间,单位是秒
lb_algo rr #设置负载调度算法,这里设置为rr,即轮询算法
lb_kind DR #设置LVS实现负载均衡的机制,有NAT、TUN、DR三个模式可选
persistence_timeout 50 #会话保持时间,单位是秒。这个选项对动态网页是非常有用的,为集群系统中的session共享提供了一个很好的解决方案。
#有了这个会话保持功能,用户的请求会被一直分发到某个服务节点,直到超过这个会话的保持时间。
#需要注意的是,这个会话保持时间是最大无响应超时时间,也就是说,用户在操作动态页面时,如果50秒内没有执行任何操作,
#那么接下来的操作会被分发到另外的节点,但是如果用户一直在操作动态页面,则不受50秒的时间限制
protocol TCP #指定转发协议类型,有TCP和UDP两种 real_server 10.0.0.137 80 { #配置服务节点1,需要指定real server的真实IP地址和端口,IP与端口之间用空格隔开
weight 3 #配置服务节点的权值,权值大小用数字表示,数字越大,权值越高,设置权值大小可以为不同性能的服务器
#分配不同的负载,可以为性能高的服务器设置较高的权值,而为性能较低的服务器设置相对较低的权值,这样才能合理地利用和分配系统资源
TCP_CHECK { #realserver的状态检测设置部分,单位是秒
connect_timeout 10 #表示3秒无响应超时
nb_get_retry 3 #表示重试次数
delay_before_retry 3 #表示重试间隔
connect_port 80
}
}
real_server 10.0.0.139 80 {
weight 3
TCP_CHECK {
connect_timeout 10
nb_get_retry 3
delay_before_retry 3
connect_port 80
}
}
}
参考:http://www.linuxde.net/2013/06/14431.html
Nginx+Keepalived主从双机热备+自动切换的更多相关文章
- nginx+keepalive主从双机热备+自动切换解决方案
环境采集cenots 6.3 64位迷你安装,因为安装前,你需要做一些工作 yum install -y make wget 如果你愿意可以更新下系统,更换下yum源. 1.安装keepalive 官 ...
- Nginx+keepalived 脚本安装主从双机热备自动切换解决方案
Nginx+keepalived 脚本安装主从双机热备自动切换解决方案 2013-07-02 19:24:13 标签:filesnginx keepalived 原创作品,允许转载,转载时请务必以超链 ...
- Keepalived+Nginx提供前端负载均衡+主从双机热备+自动切换
原文链接:http://unun.in/linux/156.html 方案: 采用两台Nginx服务器作为前端,提供静态web内容,分发web请求,一主一从,Keepalived实现状态监测,保证 N ...
- nginx:负载均衡实战(四)nginx+keepalived配置双机热备
1.下载安装 下载keepalived地址:http://www.keepalived.org/download.html 解压安装: tar -zxvf keepalived-.tar.gz 安装o ...
- nginx+keepalived实现双机热备高可用性
搭建准备: 机器两台 ip分别为192.168.100.128 192.168.100.129(能够用虚拟机測试.虚拟机网络模式为NET模式.且为静态ip) 另外须要准备一个虚拟ip对外提供服务.即通 ...
- Nginx+keepalived做双机热备加tomcat负载均衡
Nginx+keepalived做双机热备加tomcat负载均衡 环境说明: nginx1:192.168.2.47 nginx2:192.168.2.48 tomcat1:192.168.2.49 ...
- 使用keepalived实现双机热备
通常说的双机热备是指两台机器都在运行,但并不是两台机器都同时在提供服务.当提供服务的一台出现故障的时候,另外一台会马上自动接管并且提供服务,而且切换的时间非常短.下面来以keepalived结合tom ...
- Java技术中如何使用keepalived实现双机热备
Keepalived简介 Keepalived是Linux下一个轻量级别的高可用解决方案.高可用(High Avalilability,HA),其实两种不同的含义:广义来讲,是指整个系统的高可用行,狭 ...
- tomcate+keepalived配置双机热备
环境清单: 应用1:192.168.51.101 应用2:192.168.51.75 虚拟IP:192.168.51.179 一.安装Tomcat(参照其他文档): 二.部署应用,并修改响应的端口(9 ...
随机推荐
- 获取Trustedinstalled权限.reg
Windows Registry Editor Version 5.00 [HKEY_CLASSES_ROOT*\shell\runas] @="获取TrustedInstaller权限&q ...
- LocalDB简介和在VS2012及以上版本的使用
http://www.cnblogs.com/fzrain/p/3812364.html?utm_source=tuicool LocalDB简介和在VS2012及以上版本的使用 之前一不小心把自 ...
- ubuntu12.04配置静态IP及设置DNS
静态IP配置方法: 编辑/etc/network/interfaces,删掉内容,并输入以下几行(假设你的网卡是eth0) sudo gedit /etc/network/interfaces aut ...
- Metasploit自动攻击和选择模块攻击详解
Author:魔术@Freebuf.com 0×1自动攻击 终端启动Metasploit,因为我现在Source Code,所以这样启动! 连接数据库 安装方法,执行以下命令即可(请用ROOT执行). ...
- DedeCMS V5.7 Dialog目录下配置文件XSS漏洞
漏洞地址及证明:/include/dialog/config.php?adminDirHand="/></script><script>alert(1);< ...
- js控制固定div和随屏滚动div兼容多浏览器和纯css控制(来自网络)
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/ ...
- 使用 GDB 调试多进程程序
使用 GDB 调试多进程程序 GDB 是 linux 系统上常用的调试工具,本文介绍了使用 GDB 调试多进程程序的几种方法,并对各种方法进行比较. 3 评论 田 强 (tianq@cn.ibm.co ...
- 推迟调用以及Lambda表达式
背景 GMock 我们项目中现在的模块测试框架使用了CATCH+GMock的方式实现回归测试和打桩. GMock的介绍在官网上有,这里为了铺垫,大概地描述一下GMock能实现的效果.大约可以看成这样: ...
- CentOS6.5安装iftop
iftop这个小工具是Linux和unix下的top命令升级版,功能相对较强,界面易懂.今天安装了CentOS6.5的最新版,装个小工具检查下系统运行性能. 官网:http://www.ex-parr ...
- 你知道require是什么吗?
引题 用过node的同学应该都知道require是用来加载模块的,那你是否存在如下的疑问呢? 1. require(path)是如何依据path找到对应module呢? 2. 为何在模块定义中,一定要 ...