Keepalived介绍

keepalived是一个类似于layer3, 4, 5 交换机制的软件,也就是我们平时说的第3层、第4层和第5层交换。Keepalived的作用是检测web服务器的状态,如果有一台web服务器死机,或工作出现故障,Keepalived将检测到,并将有故障的web服务器从系统中剔除,当web服务器工作正常后Keepalived自动将web服务器加入到服务器群中,这些工作全部自动完成,不需要人工干涉,需要人工做的只是修复故障的web服务器

官网地址:http://www.keepalived.org

keepalved官方体系结构图:

环境准备

  1. 操作系统:CentOS6.6 64位 2台
  2. Nginx-Master   10.0.0.60
  3. Nginx-Backup   10.0.0.61
  4. VIP                      10.0.0.62

注:未做特别说明,两台服务器(两个节点)都一样操作

安装Nginx

使用《OneinStack》Nginx选择y,其余n

安装Keepalived

在Nginx-Master、Nginx-Backup:

  1. cd ~/oneinstack/src
  2. wget http://www.keepalived.org/software/keepalived-1.2.22.tar.gz
  3. tar xzf keepalived-1.2.22.tar.gz
  4. cd keepalived-1.2.22
  5. ./configure --prefix=/usr/local/keepalived
  6. make && make install

配置Keepalived

在Nginx-Master、Nginx-Backup:

  1. ln -s /usr/local/keepalived/etc/keepalived /etc/keepalived
  2. ln -s /usr/local/keepalived/etc/rc.d/init.d/keepalived /etc/rc.d/init.d/keepalived
  3. ln -s /usr/local/keepalived/etc/sysconfig/keepalived /etc/sysconfig/keepalived
  4. ln -s /usr/local/keepalived/sbin/keepalived /usr/bin/keepalived
  5. chkconfig keepalived on

在Nginx-Master修改配置文件,vi /etc/keepalived/keepalived.conf

  1. ! Configuration File for keepalived
  2. global_defs {
  3. notification_email {
  4. admin@linuxeye.com     #设置报警邮件地址,可以设置多个,每行一个。 需开启本机的sendmail服务
  5. }
  6. notification_email_from no-reply@linuxeye.com  #设置邮件的发送地址
  7. smtp_server 127.0.0.1            #设置smtp server地址
  8. smtp_connect_timeout 30    #设置连接smtp server的超时时间
  9. router_id LVS_DEVEL              #表示运行keepalived服务器的一个标识。发邮件时显示在邮件主题的信息
  10. }
  11. vrrp_script chk_nginx {
  12. script "/usr/local/keepalived/sbin/check_nginx.sh"   #该脚本检测ngnix的运行状态,并在nginx进程不存在时尝试重新启动ngnix,如果启动失败则停止keepalived,准备让其它机器接管。
  13. interval 2              #每2s检测一次
  14. weight 2               #检测失败(脚本返回非0)则优先级2
  15. }
  16. vrrp_instance VI_1 {
  17. state MASTER              #指定keepalived的角色,MASTER表示此主机是主服务器,BACKUP表示此主机是备用服务器
  18. interface eth0              #指定HA监测网络的接口
  19. virtual_router_id 55    #虚拟路由标识,这个标识是一个数字,同一个vrrp实例使用唯一的标识。即同一vrrp_instance下,MASTER和BACKUP必须是一致的
  20. priority 100                  #定义优先级,数字越大,优先级越高,在同一个vrrp_instance下,MASTER的优先级必须大于BACKUP的优先级
  21. advert_int 1            #设定MASTER与BACKUP负载均衡器之间同步检查的时间间隔,单位是秒
  22. authentication {        #设置验证类型和密码
  23. auth_type PASS      #设置验证类型,主要有PASS和AH两种
  24. auth_pass linuxeye  #设置验证密码,在同一个vrrp_instance下,MASTER与BACKUP必须使用相同的密码才能正常通信
  25. }
  26. virtual_ipaddress {     #设置虚拟IP地址,可以设置多个虚拟IP地址,每行一个
  27. 10.0.0.62
  28. }
  29. track_script {
  30. chk_nginx           #引用VRRP脚本,即在 vrrp_script 部分指定的名字。定期运行它们来改变优先级,并最终引发主备切换。
  31. }
  32. }

在Nginx-Backup修改配置文件,vi /etc/keepalived/keepalived.conf

  1. ! Configuration File for keepalived
  2. global_defs {
  3. notification_email {
  4. admin@linuxeye.com     #设置报警邮件地址,可以设置多个,每行一个。 需开启本机的sendmail服务
  5. }
  6. notification_email_from no-reply@linuxeye.com  #设置邮件的发送地址
  7. smtp_server 127.0.0.1      #设置smtp server地址
  8. smtp_connect_timeout 30    #设置连接smtp server的超时时间
  9. router_id LVS_DEVEL        #表示运行keepalived服务器的一个标识。发邮件时显示在邮件主题的信息
  10. }
  11. vrrp_script chk_nginx {
  12. script "/usr/local/keepalived/sbin/check_nginx.sh"   #该脚本检测ngnix的运行状态,并在nginx进程不存在时尝试重新启动ngnix,如果启动失败则停止keepalived,准备让其它机器接管。
  13. interval 2              #每2s检测一次
  14. weight 2                #检测失败(脚本返回非0)则优先级2
  15. }
  16. vrrp_instance VI_1 {
  17. state BACKUP            #指定keepalived的角色,MASTER表示此主机是主服务器,BACKUP表示此主机是备用服务器
  18. interface eth0          #指定HA监测网络的接口
  19. virtual_router_id 55    #虚拟路由标识,这个标识是一个数字,同一个vrrp实例使用唯一的标识。即同一vrrp_instance下,MASTER和BACKUP必须是一致的
  20. priority 50             #定义优先级,数字越大,优先级越高,在同一个vrrp_instance下,MASTER的优先级必须大于BACKUP的优先级
  21. advert_int 1            #设定MASTER与BACKUP负载均衡器之间同步检查的时间间隔,单位是秒
  22. nopreempt               #设置nopreempt防止抢占资源,只生效BACKUP节点
  23. authentication {        #设置验证类型和密码
  24. auth_type PASS      #设置验证类型,主要有PASS和AH两种
  25. auth_pass linuxeye  #设置验证密码,在同一个vrrp_instance下,MASTER与BACKUP必须使用相同的密码才能正常通信
  26. }
  27. virtual_ipaddress {     #设置虚拟IP地址,可以设置多个虚拟IP地址,每行一个
  28. 10.0.0.62
  29. }
  30. track_script {
  31. chk_nginx           #引用VRRP脚本,即在 vrrp_script 部分指定的名字。定期运行它们来改变优先级,并最终引发主备切换。
  32. }
  33. }

检测脚本,vi /usr/local/keepalived/sbin/check_nginx.sh

  1. #!/bin/bash
  2. if [ "$(ps -ef | grep "nginx: master process"| grep -v grep )" == "" ];then
  3. #echo 1
  4. /etc/init.d/nginx start
  5. sleep 5
  6. if [ "$(ps -ef | grep "nginx: master process"| grep -v grep )" == "" ];then
  7. /etc/init.d/keepalived stop
  8. #echo 2
  9. fi
  10. fi

脚本加上可执行权限

  1. chmod +x /usr/local/keepalived/sbin/check_nginx.sh

验证

  1. service keepalived start  #启动Nginx-Master
  1. service keepalived start  #启动Nginx-Backup
  1. ip addr  #2台服务器分别执行,绑定虚拟IP在Nginx-Master
  1. service keepalived stop  #停止Nginx-Backup
  1. ip addr  #2台服务器分别执行,绑定虚拟IP在Nginx-Backup
  1. service keepalived start  #再启动Nginx-Backup
  1. ip addr  #2台服务器分别执行,绑定虚拟IP在Nginx-Master

上述切换默认测试会导致的master和backup之间来回切换

通常如果master服务死掉后backup会变成master,但是当master服务又好了的时候master此时会抢占VIP,这样就会发生两次切换对业务繁忙的网站来说是不好的。我们可以在配置文件加入nopreempt非抢占,但是这个参数只能用于state为BACKUP,故我们在用HA的时候最好MASTER和backup的state都设置成BACKUP让其通过priority来竞争。

拓展

假设我要重装这2台服务器,但是过程不容许丢一个包,通常情况下先替换backup,把master停止,让vip漂移只backup,替换master,但是在vip漂移过程可能会有丢2个包,如果避免丢包?

方法:我们可以在master替换之前,利用iptables将数据包转发到backup,再停止master keepalived

  1. iptables -F
  2. iptables -t nat -I PREROUTING -i eth0 -j DNAT --to-destination 10.0.0.61
  3. iptables -t nat -I POSTROUTING -o eth0 -j MASQUERADE

Keepalived+Nginx架构整理版的更多相关文章

  1. 【Nginx】(主从热备)LVS+Keepalived+Nginx实现高性能负载均衡集群

    一.LVS 1.1 概述 1.2 Nginx与LVS区别什么 二.Keepalived 2.1 概述 2.2 keepalived和其工作原理 三.LVS+Keepalived+Nginx 搭建双机主 ...

  2. 架构设计:负载均衡层设计方案(7)——LVS + Keepalived + Nginx安装及配置

    1.概述 上篇文章<架构设计:负载均衡层设计方案(6)——Nginx + Keepalived构建高可用的负载层>(http://blog.csdn.net/yinwenjie/artic ...

  3. 搭建 Keepalived + Nginx + Tomcat 的高可用负载均衡架构

    1 概述 初期的互联网企业由于业务量较小,所以一般单机部署,实现单点访问即可满足业务的需求,这也是最简单的部署方式,但是随着业务的不断扩大,系统的访问量逐渐的上升,单机部署的模式已无法承载现有的业务量 ...

  4. [转]搭建Keepalived+Nginx+Tomcat高可用负载均衡架构

    [原文]https://www.toutiao.com/i6591714650205716996/ 一.概述 初期的互联网企业由于业务量较小,所以一般单机部署,实现单点访问即可满足业务的需求,这也是最 ...

  5. Keepalived + Nginx + Tomcat 的高可用负载均衡架构搭建

    Keepalived + Nginx + Tomcat 的高可用负载均衡架构搭建 Nginx 是一个高性能的 HTTP反向代理服务器 Keepalived 是一个基于VRRP协议来实现的LVS服务高可 ...

  6. Keepalived + Nginx + Tomcat 高可用负载均衡架构

    环境: 1.centos7.3 2.虚拟ip:192.168.217.200 3.192.168.217.11.192.168.217.12上分别部署Nginx Keepalived Tomcat并进 ...

  7. 搭建Keepalived + Nginx + Tomcat的高可用负载均衡架构

    1 概述 初期的互联网企业由于业务量较小,所以一般单机部署,实现单点访问即可满足业务的需求,这也是最简单的部署方式,但是随着业务的不断扩大,系统的访问量逐渐的上升,单机部署的模式已无法承载现有的业务量 ...

  8. Docker+Nginx+Keepalived实现架构高可用

    一.背景 通过keepalived实现nginx高可用,由于在家不想弄多台主机来搞,所以将运行环境用docker封装来模拟跨主机 docker基础镜像:centos 说之前,简单介绍一下: Keepa ...

  9. CentOS7.1下生产环境Keepalived+Nginx配置

    CentOS7.1下生产环境Keepalived+Nginx配置 [日期:2015-07-20] 来源:Linux社区  作者:soulful [字体:大 中 小]   注:下文涉及到配置的,如无特别 ...

随机推荐

  1. DataTable的子查询--DataTable.Select()

    由于需要,在sql查询获得结果集之后,又需要对该结果再进行筛选一次,若重新从sql中查询会浪费资源,因此特地去查阅了一些资料,学会了用DataTable进行子查询. 在.Net Framework 2 ...

  2. 基于HTML5的网络拓扑图

    电信网管系统中,设备状态信息的实时展示非常重要,通常会挂载一堆图标来展示状态或告警信息,图标的信息量有限,有时需要更详细的面板,甚至以图表的形式展现,本文将结合最近客户提到的需求,使用 Qunee1. ...

  3. maven 配置

    四.eclipse配置maven eclipse---window---maven------User Settings: 之前设置的仓库的位置: 五.idea15配置maven idea14---s ...

  4. #include <vector>用法之我见

    vector是一种顺序容器,事实上和数组差不多,但它比数组更优越.一般来说数组不能动态拓展,(何为动态拓展,即是说如果你知道你要存的数据的个数,你定义的存储数据的数组大小也就决定了,但是若你事先不知道 ...

  5. 如何在Form++开源组态平台添加硬件采集接口

    E-Form++是一套值得推荐的高品质开源C++矢量图形库,C++编程之所以异常困难,主要就是没有很专业的C++基础架构库有关.E-Form++的出现一定程度上填补了这个空白.是开发工控.监控.建模与 ...

  6. node.js实用小模块

    1.浮点数操作 npm install float 2.MD5加密类 npm install MD5 3.xml解析类 1 npm install elementtree 4.转换字符串大小写 1 n ...

  7. WordPress博客平台的搭建--基于Ubuntu14服务器

    环境:阿里云服务器,系统Ubuntu14.04, 阿里云域名 大致流程:LNMP+WordPress 主要参考博客:VPS+LNMP+WordPress搭建个人网站/博客 遇到的问题: 1.在登陆域名 ...

  8. BZOJ 2898 模拟

    普及组水题. 按位模拟第一个序列和第二个序列,细节比较多.. 仅为部分看后面两位的和,如果大于10就近位小于8就不进位等于9就看下一位. #include <cstdio> #define ...

  9. mysql数据库引擎 MyISAM和 InnoDB区别

    1. 存储结构 MyISAM:每个MyISAM在磁盘上存储成三个文件.第一个文件的名字以表的名字开始,扩展名指出文件类型..frm文件存储表定义.数据文件的扩展名为.MYD (MYData).索引文件 ...

  10. POJ2653判断直线是否相交

    bool judge(node p1,node p2,node p3,node p4){    if(min(p1.x,p2.x)>max(p3.x,p4.x)||min(p1.y,p2.y)& ...